Overview
The line-interactive SMART5000RT3U UPS System protects server, networking or telecommunications equipment from blackouts, voltage fluctuations and surges in a compact tower/rack-mount housing. In rack configuration, the power module and battery pack occupy only 3U each. Large-capacity 5000VA/4000W power module converts raw 208V AC input to fully regulated dual-output 208/120 voltage for simultaneous protection of both high- and low-voltage equipment loads. True sine wave output at all times offers guaranteed compatibility with all equipment types. Includes 14 outlets, eight of which can be individually reset via software interface to selectively reboot remote equipment or shed less critical loads to extend battery runtime for more critical equipment. Battery support can be extended indefinitely with additional external 3U rack-mount battery packs. Includes slot for internal Network Management Card option. Also includes two DB9 and two USB enhanced monitoring ports for unattended shutdown, remote control and monitoring of UPS system and power data.
OVERVIEW
| UPC Code |
037332099242 |
| UPS Type |
Line-Interactive |
INPUT
| Input Phase |
Single-Phase |
| Rated input current (Maximum Load) |
24A max. in factory L6-30P configuration; 27A max. when powered by 50A plug or hardwire input |
| Nominal Input Voltage(s) Supported |
208V AC |
| UPS Input Connection Type |
L6-30P |
| Input Circuit Breakers |
30A double-pole |
| UPS Input Cord Length (ft.) |
10 |
| Recommended Electrical Service |
30A 208V |
| Maximum Input Amps |
24 |
OUTPUT
| Output Capacity (VA) |
5000 |
| Output Capacity (kVA) |
5 |
| Output Capacity (Watts) |
4000 |
| Output Capacity (kW) |
4 |
| Output Capacity Details |
Maximum output increases to 4800W when hardwire or user-supplied 50A rated input plug is used |
| Power Factor |
0.8 |
| Nominal Voltage Details |
208/120V nominal output in battery mode |
| Frequency Compatibility |
60 Hz |
| Output Voltage Regulation (Line Mode) |
208 & 120V (-10% / +10%) |
| Output Voltage Regulation (Battery Mode) |
+/- 5% |
| Load Management Receptacles |
Eight switchable single-outlet 5-15R load banks |
| Output Circuit Breakers |
15A branch rated (x3) - 2 breakers support 5 5-15R outlets each, one breaker supports 2 5-20R outlets, L6-30R and L14-30R outlets are unbreakered |
| Output AC Waveform (AC Mode) |
Sine wave |
| Output AC Waveform (Battery Mode) |
Pure Sine wave |
| Nominal Output Voltage(s) Supported |
110V; 115V; 120V; 208V |
| Output Receptacles |
(10) 5-15R; (2) 5-15/20R; (1) L14-30R; (1) L6-30R |
| Individually Controllable Load Banks |
Yes |
BATTERY
| Battery Type |
Valve Regulated Lead Acid (VRLA) |
| Runtime Full Load (min.) |
16 min. (4000W) |
| Runtime Half Load (min.) |
38 min. (2000W) |
| Expandable Runtime |
Yes |
| External Battery Pack Compatibility |
BP48V24-2U (limit 1); BP48V60RT-3U (multi-pack compatible); BP48V27-2US (multi-pack compatible) |
| DC System Voltage (VDC) |
48 |
| Battery Recharge Rate (Included Batteries) |
Less than 4 hours from 10% to 90% (typical, full load discharge) |
| Battery Replacement Description |
Hot-swappable, user replaceable batteries |
VOLTAGE REGULATION
| Voltage Regulation Description |
Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 151 to 260 |
| Overvoltage Correction |
Input voltages between 240V and 260 are reduced by 12% |
| Undervoltage Correction |
Input voltages between 180V and 199 are boosted by 12% |
| Severe Undervoltage Correction |
Input voltages between 151V and 179 are boosted by 24% |
USER INTERFACE, ALERTS & CONTROLS
| Switches |
2 Switches control off/on power status and alarm-cancel/self-test operation |
| Alarm Cancel Operation |
Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status |
| Audible Alarm |
Audible alarm indicates power-failure, overload and low-battery conditions |
| LED Indicators |
5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status |
SURGE / NOISE SUPPRESSION
| EMI / RFI AC Noise Suppression |
Yes |
| AC Suppression Joule Rating |
1020 |
| AC Suppression Response Time |
Instantaneous |
PHYSICAL
| Primary Form Factor |
Rackmount |
| Rack Height |
6U |
| Cooling Method |
Fans |
| Included Battery Pack Dimensions (hwd / in.) |
5.2 x 17.5 x 25 |
| Included Battery Pack Weight (lbs.) |
163 |
| Installation Form Factors Supported with Included Accessories |
4 post 19 inch rackmount |
| Installation Form Factors Supported with Optional Accessories |
2 post rackmount ( 2POSTRMKITHD ); 4 post rackmount short-depth ( 4POSTRAILKITWM ); Tower ( 2-9USTAND ) |
| Minimum Required Rack Depth (inches) |
3 |
| Minimum Required Rack Depth with External Battery Pack (cm) |
75 |
| Minimum Required Rack Depth with External Battery Pack (in.) |
29.5 |
| Minimum Required Rack Depth without External Battery Pack (cm) |
72 |
| Minimum Required Rack Depth without External Battery Pack (in.) |
28.25 |
| Optional Mounting Accessory Notes |
Optional 2-9USTAND enables upright tower UPS placement (1 required); 2POSTRMKITHD enables 2-post rackmount installation (2 required); 4POSTRAILKITWM enables installation in 4-post short-depth racks from 14.5 to 23.5 inches (368 to 597mm, requires 2) |
| Primary UPS Depth (mm) |
572 |
| Primary UPS Height (mm) |
132 |
| Primary UPS Width (mm) |
445 |
| Shipping Dimensions (hwd / in.) |
24.50 x 24.00 x 34.00 |
| Shipping Weight (lbs.) |
321.62 |
| Unit Dimension Details |
Includes 3U UPS/power module and 3U external battery pack |
| UPS Housing Material |
Steel |
| UPS Power Module Dimensions (hwd, in.) |
5.2 x 17.5 x 22.5 |
| UPS Power Module Weight (kg) |
42.18 |
| UPS Power Module Weight (lbs.) |
93 |
| Unit Weight (lbs.) |
321.62 |
| Mounting Details |
Set of two included 4POSTRAILKIT mounting brackets enables installation of UPS and Battery Pack in 4 post racks from 20.5 to 36 inches (521 to 914mm) |
ENVIRONMENTAL
| Operating Temperature Range |
32° to 104°F (0° to 40°C) |
| Storage Temperature Range |
5° to 122°F (-15° to 50°C) |
| Relative Humidity |
0-95% non-condensing |
| AC Mode Efficiency Rating (100% Load) |
94% |
| Battery Mode Heat Dissipation (BTU/Hr) @ Full Load |
1518 |
| Audible Noise |
45 dBA maximum, front side 1m |
COMMUNICATIONS
| Network Management Cards |
WEBCARDLXE |
| Network Monitoring Port Description |
Supports detailed monitoring of UPS and site power conditions; 2 USB ports, 1 DB9 serial and 1 DB9 contact closure port (4 total) |
| PowerAlert Software |
For local monitoring via the UPS’s built-in communication ports, download PowerAlert software at https://tripplite.eaton.com/products/power-alert |
| Communications Cable |
USB and DB9 cabling included |
| WatchDog Compatibility |
Supports Watchdog application, OS and hard-reboot restart options for remote applications |
| Network Management Card Description |
Network management card optional |
| Communications Interface |
Contact closure; DB9 Serial; USB |
LINE / BATTERY TRANSFER
| Transfer Time |
2-4 milliseconds |
| Low Voltage Transfer to Battery Power (Setpoint) |
151 |
| High Voltage Transfer to Battery Power (Setpoint) |
260 |
FEATURES & SPECIFICATIONS
| Cold Start (Startup in Battery Mode During a Power Failure) |
Cold-start operation supported |
| High Availability UPS Features |
Automatic Voltage Regulation (AVR); Hot swappable batteries; Surge/noise protection |
| Grounding Details |
Back panel grounding lug |
APPLICATIONS
| UPS Applications |
Large Network |
STANDARDS & COMPLIANCE
| Product Certifications |
CSA (Canada); NOM (Mexico); UL 1778 |
| Product Compliance |
RoHS; FCC Part 15 Class A (USA) |