null
EATON

Eaton Tripp Lite series SmartPro 208 & 120V 5kVA 3.75kW Line-Interactive Sine Wave UPS, 3U, Extended Run, Network Card Options, USB, DB9, TAA

(No reviews yet) Write a Review
SKU:
SMART5000XFMRXL
MPN:
SMART5000XFMRXL
  • Eaton Tripp Lite series SmartPro 208 & 120V 5kVA 3.75kW Line-Interactive Sine Wave UPS, 3U, Extended Run, Network Card Options, USB, DB9, TAA
  • Eaton Tripp Lite series SmartPro 208 & 120V 5kVA 3.75kW Line-Interactive Sine Wave UPS, 3U, Extended Run, Network Card Options, USB, DB9, TAA
  • Eaton Tripp Lite series SmartPro 208 & 120V 5kVA 3.75kW Line-Interactive Sine Wave UPS, 3U, Extended Run, Network Card Options, USB, DB9, TAA
  • Eaton Tripp Lite series SmartPro 208 & 120V 5kVA 3.75kW Line-Interactive Sine Wave UPS, 3U, Extended Run, Network Card Options, USB, DB9, TAA
$6,921.00
Frequently bought together:

Description

Overview

5000VA line-interactive UPS for server, network and telecommunications equipment with internal batteries requires 3U installed. Accepts 208V nominal input voltage. Simultaneous 208V and 120V output. Corrects brownouts and over voltages from 167V to 260V. Sine wave output. Maintains battery-derived AC output during blackouts and severe voltage fluctuations. Expandable runtime with optional external battery packs. Eleven output receptacles. NEMA L6-30P input connection with support for user-supplied 50A or hardwire input. Network-grade AC surge and noise suppression. Network management interfaces include USB, DB9 serial and slot for Network Management Card options. Supports simultaneous detailed monitoring of equipment load levels, self-test data and utility power conditions via all network interfaces simultaneously. Power Alert® UPS monitoring software is available via free download. Emergency Power Off (EPO) interface. Integrated eight-bank switched PDU. Three-stage metered current monitoring and battery charge LEDs. Utility power and voltage regulation LEDs. Audible alarm. Self-test. 4-post rack-mounting accessories included; 2-9USTAND and 2POSTRMKITHD accessories available. Field-replaceable, hot-swappable internal batteries and battery packs.

  • 5000VA/3750 watt max. output power capacity compatible with North American 208V/60 Hz input voltage
  • Supports full output at either 208V or 120V
  • 3U rack/tower UPS installs in standard 19-inch rack enclosures with an installed depth of only 25 inches / 63.5cm
  • Protects sensitive networking equipment from blackouts, voltage fluctuations and transient surges
  • Line Interactive Automatic Voltage Regulation (AVR) corrects 208V nominal input from 167 to 260VAC back to usable 208/120V levels without consuming battery power
  • AVR circuits boost undervoltages by 12% and reduce overvoltages by 12%
  • Network interfaces support simultaneous communications via USB, DB9 serial and slot for Network Management Card option
  • Compatible with UPS management card options TLNETCARD, WEBCARDLX and SNMPWEBCARD
  • USB & Serial ports enable data-saving unattended shutdown when used with PowerAlert software, available via FREE download from tripplite.eaton.com/products/power-alert
  • Built-in Emergency Power Off (EPO) interface with cable
  • Sine wave output in AC and battery mode
  • Expandable runtime with optional BP48V60RT-3U and BP48V27-2US external battery packs
  • Half/full load runtime of 20/8.5 minutes with internal batteries
  • Intelligent battery management system extends battery life
  • Includes 11 output receptacles (2 L6-20, 1 L6-30 & 8 NEMA 5-15/20R)
  • Ships with installed L6-30P input plug, supports user supplied 50A replacement plug or hardwire input
  • Integrated 8 bank switched PDU enables remote outlet management for load shedding or remote reboot of individual devices
  • 3 stage metered LEDs offer current monitoring and battery charge level
  • Mains power and voltage regulation LEDs offer at-a-glance power status information
  • Front panel switches support self-test and alarm cancel functions
  • Included adjustable mounting rails support installation in 4-post 19-inch racks
  • UPS ships fully assembled in full compliance with DOT regulations, no time consuming connection of internal batteries by user is required
  • Supports upright tower placement with optional 2-9USTAND accessory

 

Specifications

OVERVIEW
UPC Code 037332121462
UPS Type Line-Interactive
INPUT
Input Phase Single-Phase
Rated input current (Maximum Load) 24A
Nominal Input Voltage(s) Supported 208V AC
UPS Input Connection Type L6-30P
UPS Input Cord Length (ft.) 10
Recommended Electrical Service 30A 208V
Maximum Input Amps 24
OUTPUT
Output Capacity (VA) 5000
Output Capacity (kVA) 5
Output Capacity (Watts) 3750
Output Capacity (kW) 3.75
Power Factor   0.75
Nominal Voltage Details 208/120V nominal output in battery mode
Frequency Compatibility 60 Hz
Output Voltage Regulation (Line Mode) 208 & 120V (+/- 10%)
Output Voltage Regulation (Battery Mode) +/- 5%
Load Management Receptacles   Eight switchable single-outlet 5-15/20R load banks
Output Circuit Breakers 20A double pole breaker supports L6-20R outlets, 20A branch rated breaker (x2) supports 4 5-15/20R outlets each, L6-30R outlet is unbreakered
Output AC Waveform (AC Mode) Sine wave
Output AC Waveform (Battery Mode) Pure Sine wave
Nominal Output Voltage(s) Supported 110V; 115V; 120V; 208V
Output Receptacles (8) 5-15/20R; (2) L6-20R; (1) L6-30R
Individually Controllable Load Banks   Yes
BATTERY
Battery Type Valve Regulated Lead Acid (VRLA)
Runtime Full Load (min.)   8.5 min. (3750W)
Runtime Half Load (min.)   20 min. (1875W)
Expandable Runtime Yes
External Battery Pack Compatibility    BP48V27-2US  (multi-pack compatible); BP48V60RT-3U (multi-pack compatible)
DC System Voltage (VDC) 48
Battery Recharge Rate (Included Batteries) 6.8 hours from 10% to 90% (typical, full load discharge)
Battery Access Front panel battery access door
Internal UPS Replacement Battery Cartridge  RBC94-3U  (quantity 3)
Battery Replacement Description Hot-swappable, user replaceable batteries
VOLTAGE REGULATION
Voltage Regulation Description Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 167 to 260
Overvoltage Correction   Input voltages between 228 and 260 are reduced by 12%
Undervoltage Correction   Input voltages between 167 and 194 are boosted by 12%
USER INTERFACE, ALERTS & CONTROLS
Switches 2 Switches control off/on power status and alarm-cancel/self-test operation
Alarm Cancel Operation Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status
Audible Alarm Audible alarm indicates power-failure, overload and low-battery conditions
LED Indicators 5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status
SURGE / NOISE SUPPRESSION
EMI / RFI AC Noise Suppression   Yes
AC Suppression Joule Rating   1020
AC Suppression Response Time  

Instantaneous

 

PHYSICAL
Primary Form Factor Rackmount
Rack Height   3U
Cooling Method Fan
Installation Form Factors Supported with Included Accessories 4 post 19 inch rackmount
Installation Form Factors Supported with Optional Accessories 2 post rackmount ( 2POSTRMKITHD ); Tower ( 2-9USTAND )
Minimum Required Rack Depth (inches) 28
Minimum Required Rack Depth with External Battery Pack (cm) 81
Minimum Required Rack Depth with External Battery Pack (in.) 32
Minimum Required Rack Depth without External Battery Pack (cm) 76
Minimum Required Rack Depth without External Battery Pack (in.) 30
Primary UPS Depth (mm) 635
Primary UPS Height (mm) 132
Primary UPS Width (mm) 445
Shipping Dimensions (hwd / in.) 12.00 x 23.00 x 33.00
Shipping Weight (lbs.) 191.33
UPS Housing Material Steel
UPS Power Module Dimensions (hwd, in.) 5.2 x 17.5 x 25
UPS Power Module Weight (kg) 65.00
UPS Power Module Weight (lbs.) 143.3
Unit Weight (lbs.) 143.3000
ENVIRONMENTAL
Operating Temperature Range 32° to 104°F (0° to 40°C)
Storage Temperature Range 5° to 122°F (-15° to 50°C)
Relative Humidity 5 to 95%, non-condensing
AC Mode BTU / Hr. (Full Load)   366
AC Mode Efficiency Rating (100% Load) 97%
Audible Noise 45 dBA maximum, front side 1m
COMMUNICATIONS
Network Management Cards  TLNETCARD ;  WEBCARDLXE 
Network Monitoring Port Description Supports detailed monitoring of UPS and site power conditions
PowerAlert Software For local monitoring via the UPS’s built-in communication ports, download PowerAlert software at https://tripplite.eaton.com/products/power-alert
Communications Cable USB and DB9 cabling included
WatchDog Compatibility Supports Watchdog application, OS and hard-reboot restart options for remote applications
Network Management Card Description Network management card optional
Communications Interface DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface; USB
LINE / BATTERY TRANSFER
Transfer Time   7 ms (AC to Battery); 1 ms (Battery to AC) typical
Low Voltage Transfer to Battery Power (Setpoint) 167
High Voltage Transfer to Battery Power (Setpoint) 260
FEATURES & SPECIFICATIONS
Cold Start (Startup in Battery Mode During a Power Failure) Cold-start operation supported
High Availability UPS Features   Auto Probe Monitoring and Reboot (requires WEBCARDLX); Automatic Voltage Regulation (AVR); Hot swappable batteries; Remote management; Surge/noise protection
Green Energy-Saving Features Greater than 95% efficiency - GREEN UPS; Individually controllable load banks
Grounding Details Back panel grounding lug
APPLICATIONS
UPS Applications Large Network
STANDARDS & COMPLIANCE
Product Certifications CSA (Canada); CAN/CSA-C22.2 No. 107.3 (Canada); IEC/EN 62040; NOM (Mexico); UL 1778
Product Compliance RoHS; FCC Part 15 Class A (USA); Trade Agreements Act (TAA)
View AllClose