null
Altronix

Altronix AL600ULM Access Power Distribution Module w/ Power Supply/Charger, 5 PTC Class 2 Outputs, 12/24VDC @ 6A, FAI, 115VAC, BC300 Enclosure

(No reviews yet) Write a Review
SKU:
AL600ULM
MPN:
AL600ULM
$508.21

Please contact for availability

Description

AL600ULM multi-output access control power supply/charger is specifically designed for use with access control systems and accessories. This unit converts a 115VAC, 60Hz input into five (5) individually protected Class 2 Rated power limited 12VDC or 24VDC outputs. Each output will route power to a variety of access control hardware devices including Mag Locks, Electric Strikes, Magnetic Door Holders, etc. These outputs will operate in both Fail-Safe and Fail-Secure modes. Controlled trigger input is achieved through normally open (N.O.) or normally closed (N.C.) supervised input or the polarity reversal from an FACP (Fire Alarm Control Panel). A form "C" dry output relay enables HVAC Shutdown, Elevator Recall or it may be used to trigger auxiliary devices.

 

 Specifications

  • Input
    • Input 115VAC, 60Hz, 3.5A.
    • Input fuse rated @ 3.5A/250V.
    • Fire Alarm Panel or Access Control System trigger inputs. N.O. or N.C. supervised trigger input and polarity reversal trigger input.
  • Output
    • 12VDC or 24VDC selectable outputs.
    • 6A supply current.
    • Five (5) PTC protected Class 2 Rated power limited outputs, rated @ 2A (auto-resettable).
    • Output relay energizes when unit is triggered (form "C" contact rated 1A @ 28VDC).
    • Filtered and electronically regulated output.
    • Short circuit and thermal overload protection.
  • Battery Charging
    • Built-in charger for sealed lead acid or gel type batteries.
    • Automatic switch over to stand-by battery when AC fails.
    • Zero voltage drop when switching over to battery backup.
    • (Batteries are sold separately).
  • Supervision
    • AC fail supervision (form "C" contacts).
    • Notification trigger is selectable for 30 seconds (factory set) or 6 hours.
    • Low battery supervision (form "C" contacts).
    • Battery presence supervision (form "C" contacts).
    • Power fail supervision relay (form "C" contacts).
  • Visual Indicators
    • AC input and DC output LED indicators (power supply board).
    • Red LEDs indicate condition of power outputs (multi-output board).
    • Power & input trigger LEDs (multi-output board).
  • Temperature
    • Operating: 0° C to 49° C (32° F to 120° F).
    • Storage: - 20° C to 70° C ( - 4° F to 158° F).
    • Relative Humidity: 85% +/- 5%.
      • BTU/Hr. (approx.):
        • 12VDC: 37 BTU/Hr.
        • 24VDC: 74 BTU/Hr.
    • System AC input VA requirement: 166.75VA.
View AllClose